BS EN IEC 63086-1:2020 pdf free.Household and similar electrical air cleaning appliances一Methods for measuring the performance.
BS EN IEC 63086-1 This part of IEC 63086 applies to electrically powered household and similar air cleaners intended for use on rated single-phase AC input voltage circuits not exceeding 250 V and DC input voltage circuits not exceeding 48 V. NOTE 1 See Clause 4 for examples of different technologies and placements of household and similar air cleaners. NOTE 2 If the test methods in this document are applied to combination products (air conditioners, humidifiers, dehumidifiers, heaters, etc.) with air cleaning function, they are only aimed at their air cleaning function when tested. NOTE 3 Battery-operated appliances are within the scope of this document. Dual-supply appliances, either mains- supplied or battery-operated, are regarded as battery-operated appliances when operated in the battery mode. NOTE 4 This document is not applicable to: ● appliances intended exclusively for industrial purposes; appliances intended for use in medical treatment locations, such as surgical suites, laboratories, medical treatments rooms, etc. ● household range hoods or cooking fume extractors – see IEC 61591.The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60704 (all parts), Household and similar electrical appliances 一Test code for the determination of airborne acoustical noise IEC 62301:201 1, Household electrical appliances一Measurement of standby power.A robotic air cleaner shall be placed ina 1 m2 ((1,00土0,05)m x (1,00土0,05) m) square area with perforated stainless-steel walls of 100 mm in height. Placement of a direct plug-in type air cleaner An air cleaner that is intended for direct plug-in mounting to the electrical mains receptacle shall be placed on a test stand described in Annex C. Placement of an air cleaner not specified Where the placement of the air cleaner is not specified by the manufacturer, the DUT shall be classified according to its height. If the height of the DUT is less than 0,7 m from the floor, the DUT shall be placed on a table of 0,7 m in height. In all other cases, the DUT shall be placed on the floor of the test chamber. BS EN IEC 63086-1 pdf download.
BS EN IEC 63086-1:2020 pdf free
ATTENTION:
I REALLY NEED YOUR SUPPORT.THANKS A LOT.