BS ISO 8102-1:2020 pdf free

05-22 comment

BS ISO 8102-1:2020 pdf free.Electrical requirements for lifts,escal ators and moving walks.
The electromagnetic emission levels at each machine/motor port (conductive) of the apparatus/assembly of apparatus shall not exceed the limits specified in Table 3. If shielded connectors and shielded cables, in accordance with the apparatus/assembly of the apparatus manufacturer’s specifications, are used for machine/motor ports, or the cables are less than or equal to 2 m long, measurements at those ports are not necessary.The requirements of IEC 61000-3-11 apply to a system. Voltage fluctuations are dependent on the impedance of the mains supply for an individual system and the characteristics of the apparatus/assembly of apparatus. The manufacturer shall document the maximum impedance of the electricity mains supply for the system.Apparatus/assembly of apparatus using controlled speed drives are known not to be a cause of voltage flicker disturbance. However, direct on line or star-delta starting of escalator motors, hoisting and hydraulic pump motors and repetitive direct switching of highly inductive loads (e.g. transformer) should be treated with caution.The limits of Tables 4 to 6 apply to a balanced three-phase system (equipment) or a hybrid system (equipment) in one of the following circumstances: a) hybrid equipment having a maximum third harmonic current of less than 5 % of the reference current; or b) there is provision in the construction of hybrid equipment to separate the balanced three-phase and the single-phase or interphase loads for the measurement of supply currents, and when the current is being measured, the part of the equipment being measured draws the same current as under normal operating conditions. In that case, the relevant limits shall be applied separately to the single-phase or interphase part and to the balanced three-phase part. Table 4, Table 5 or Table 6 applies to the current of the balanced three-phase part, even if the rated current of the balanced three-phase part is less than or equal to 16 A per phase. Table 7 applies to the current of the single-phase or interphase part but, if the rated current of the single-phase or interphase part is less than or equal to 16 A, the relevant limits of IEC 61000-3-2 to the single-phase or interphase part can be applied instead of the limits stated in Table 7.BS ISO 8102-1 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
BS ISO 24081:2021 pdf download BS pdf free download

BS ISO 24081:2021 pdf download

BS ISO 24081:2021 pdf download.Ground cassava leaves (Isombe) — Specification. 1 Scope This document specifies requirements and methods of sampling and testing for ground cassava leaves, which are obtained from the processing of fresh cassava leaves (Manihot esculenta Crantz or Manihot glaziovii) intended for human consumption. 2 Normative references The following documents are referred to in the text in such...
Download

BS EN 1463‑2:2021

BS EN 1463‑2:2021 pdf download.Road marking materials — Retroreflecting road studs Part 2: Road test performance specifications. 4 Test sites and conditions 4.1 General Test sites shall be arranged at suitable locations that meet at least the requirements of 4.2 to 4.5. The test results will depend on the weather, traffic and road surface conditions. These shall all be described...
Download
BS ISO 3739‑2:2021 pdf download BS pdf free download

BS ISO 3739‑2:2021 pdf download

BS ISO 3739‑2:2021 pdf download.Industrial tyres and rims Part 2: Pneumatic tyres (metric series) on 5 degrees tapered or flat base rims — Load ratings. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited...
Download

LEAVE A REPLY

Anonymous netizen Fill in information