BS EN 4838-005:2019 pdf free.Aerospace series – Arc fault circuit breakers, singlepole, temperature compensated, rated current 3 Ato 25A- 115 V a.c. 400 Hz Constant Frequency.
2,Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3155-016, Aerospace series一Electrical contacts used in elements of connection一Part 016: Contacts, electrical, male, type A, crimp, class S一Product standard EN 3841-100, Aerospace series一Circuit breakers一Test Methods 一Part 100: General EN 4838-001, Aerospace series 一Arc Fault Circuit breakers, single-pole, temperature compensated, rated current3A to25A一115 Vac 400 Hz constant frequency一Part 001: Technical specification EN 6113, Aerospace series一Circuit breakers, connecting and attachment hardware TR 6083, Aerospace series一Cut-outs for installation of electrical components 1) MIL-S- 19500B, Semiconductor Device, Diode, Type 1N969 (Navy) 2) MIL-I-81969/1, Installing and removal tools, connector electrical contact, Type II,, Class 2, composition C2) MIL-I-81969/14, Installing and removal tools, connector electrical contact, Type II, Class 2, composition B2) FED-STD-595B, Colors used in Government Procurement 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 3841-100 apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: ●IEC Electropedia: available at http://www.electropedia.org/ ●ISO Online browsing platform: available at http://www.iso.org/obp 4 Dimension and mass 4.1 Dimensional characteristics The circuit breakers do not have to correspond to the pictorial illustration, only the dimensions given shall be adhered to. See Figure 1. Dimensions are in millimetres with exception Terminal thread 8-32 UNC.4.4 Panel mounting Panel cut-out The panel cut-out is in accordance with the designation TR 6083C202. Spacing 20 mm horizontal and 35 mm vertical from the centre of the mounting holes. Panel thickness 1mmto3mm. The metallic front plate of the breaker (mark 15 on Figure 1) is an electrical connection to neutral. For this purpose the panel mounting means must ensure a good electrical continuity to neutral. In case of panel isolated from neutral a rear wire can be used to connect neutral to terminal 6 (see Figure 1).BS EN 4838-005 pdf download.
BS EN 4838-005:2019 pdf free
ATTENTION:
I REALLY NEED YOUR SUPPORT.THANKS A LOT.