AS 1657:2018 pdf free

02-23 comment

AS 1657:2018 pdf free.Fixed platforms, walkways, stairways and ladders – Design, construction and installation.
This Standard sets out requirements for the design, selection, construction and installation of fixed platforms, walkways, stairways and ladders that are intended to provide safe access to places used by operating, inspection, maintenance and servicing personnel.
This Standard also applies to the following:
(a)Movable platforms that are permanently configured but that may be site adjustable or site assembled/modified.
(b)Permanently installed roof access, where such access is for the purpose of installing,operating, inspecting, maintaining or servicing equipment that is located on, or is accessible from. the roof.
(c)Permanently installed access for inspection and maintenance of the roof itself.
NOTES:
In the absence of a directly applicable Standard, this Standard may be used for guidance in providing access to some parts of stationery and mobile machinery, light and telecommunication towers, wind turbine towers and water and sewerage facilities. While such access may not be capable of conforming to all the requirements of this Standard, the principles and imposed actions should be followed.
2 Appendix A provides information on recommended component dimensions and materials for edge protection.
3 Appendix F provides a method for testing the load-carrying capacity of a twin-stile or single-stile fixed ladder.
Appendix G provides information on selection of stairways, walkways and fixed ladders.
5 Appendix H provides guidelines for fall protection measures for various types of ladders.
6 Appendix I provides design, fabrication and installation considerations for ladders to improve their safety and reduce the likelihood of injury to users.
7 Appendix J provides guidelines for roof access for the purposes of routine equipment or building maintenance activities.
1.2 EXCLUSIONS
This Standard does not apply to the following:
(a) Scaffolding that may be used in similar situations.
(b)Access for people with disabilities.
(c)Temporary access, e.g. by means of portable ladders.
(d) Access and egress to buildings covered by the National Construction Code(NCC).
(e)Attic type ladders(see Note 1).
(f) Access to lift machine rooms (see Note 2).

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download