AS NZS 5263.1.3:2016 pdf free

09-06 comment

AS NZS 5263.1.3:2016 pdf free.Gas appliances Part 1.3: Gas space heating appliances.
2.7.102 Safety controls for exposed burners
Appliances fitted with exposed burners shall not have exposed controls capable of
activating and sustaining ignition by momentary operation.
2.8 GAS TRAIN
This Clause of AS 5263.0 applies.
2.9 COMBUSTION AIR AND FLUE SYTEMS
This Clause of AS 5263.0 applies, except as modified below.
2.9.5 Design of flue connection
The flue connection shall provide means to prevent partial or complete blockage of flueways caused by the fitting of a flue pipe. The minimum length of engagement shall be not less than 13 mm for a vertical flue connection and 25 mm for a horizontal flue connection.
In addition, for Australia, flue connections shall comply with the following:
(a) A horizontal flue connection on an open flued appliance having a gas consumption of up to 50 Mi/h shall be a rectangular spigot of nominal dimensions 250 mm x 50 mm, conforming to the requirements of Table 2.9.5.2. The use of an adaptor whose termination conforms to these dimensions and which is supplied with the appliance shall be considered satisfactory.
(b) A vertical flue connection on an open flued appliance having a gas consumption of up to 50 Mi/h shall be a spigot suitable for connection to twin wall metal flue complying with AS 4567. The use of an adaptor meeting this requirement and supplied with the appliance shall be considered satisfactory.
(c) A vertical or horizontal flue connection on an open flued appliance having a gas consumption greater than 50 MJ/h shall be designed to accommodate both single wall and twin wall circular or rectangular metal flue pipes. The use of an adaptor to achieve this purpose shall be considered satisfactory.
(d) Flue connections or adaptors designed only for a single wall metal flue pipe shall conform with the dimensions in Table 2.9.5.1 and Table 2.9.5.2.
Or
(e) The flue connection shall be suitable for a flue that is specified by the manufacturer. 2.9.10 1 Combustion products temperature limit device
If the appliance is intended to be connected to a flue likely to be adversely affected by abnormal temperature of the combustion product (e.g. a plastics flue or a plastics-lined flue), the appliance shall have a device that prevents the combustion products temperature from exceeding the maximum permissible temperature declared by the manufacturer.
This device shall not be adjustable and shall not be accessible without a tool. The action of this device shall result in a non-volatile lockout of the appliance.
2.9.102 Circulating air system
Appliances shall be so constructed that there is no leakage of circulating air into the heat exchanger or of flue products into the circulating air system.AS NZS 5263.1.3 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information