AS NZS 60598.2.5:2018 pdf free

09-07 comment

AS NZS 60598.2.5:2018 pdf free. Luminaires Part 2.5: Particular requirements- Floodlights (IEC 60598-2-5:2015 (ED.3.0), MOD).
5.5 Marking
The provisions of Section 3 of IEC 60598-1 apply. In addition, the following information shall be provided in the instruction leaflet supplied with the luminaire, if applicable:
a) operating position, if not universal;
b) weight and overall dimensions of the floodlight;
c) maximum projected area of the floodlight;.
d) limitation of use indoors and/or outdoor;
5.6 Construction
The provisions of Section 4 of lEO 60598-1 apply together with the requirements of 5.6.1 to 5.6.8.
5.6.1 Floodlights for use outdoors shall have protection against the ingress of moisture at least equivalent to IPX3.
5.6.2 Lampholder brackets and lamp supports where used shall withstand normal usage throughout the life of the floodlight. They shall accept and retain lamps which are within the dimensional tolerances stated in the appropriate lEO publication where applicable, and locate the lamp or lamps in the designed relationship to the optical control devices in the floodlight.
5.6.3 When provision is made for alternative sizes of lamps or light centre positions, the adjusting means shall be positive and firmly retained in the selected position.
5.6.4 Refractors, reflectors or any other light controlling components shall be so marked or constructed that they can be fitted or replaced only in the correct relationship to the light source.
5.6.5 The means for attaching the floodlight to its support shall be appropriate to the weight of the floodlight.
For floodlights for use above ground level outdoors, the connection shall withstand wind speeds of 150 km/h on the projected surface of the floodlight assembly without undue deflection.
Fixings which carry the weight of the floodlight and internal accessories shall be provided with appropriate means to prevent the dislodgement of any part of the floodlight by vibration, either in service or during maintenance.
Parts of floodlights for mounting heights of 3 m or higher which are fixed other than with at least two devices, for example, screws or equivalent means of sufficient strength, shall have such extra protection as to prevent those parts falling and endangering persons, animals and surroundings, if a fixing device fails under normal conditions. The points of attachment which allow the floodlight to rotate and which are tested below are excluded from the requirements of this paragraph.
Compliance shall be checked by inspection and, for floodlights for use above ground level outdoors, by the additional following test.
The floodlight is mounted with its largest projected area as viewed in elevation lying in the horizontal plane, and with the means of attachment secured in accordance with the manufacturer’s recommendations.AS NZS 60598.2.5 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information