AS NZS 60598.2.5:2018 pdf free. Luminaires Part 2.5: Particular requirements- Floodlights (IEC 60598-2-5:2015 (ED.3.0), MOD).
5.5 Marking
The provisions of Section 3 of IEC 60598-1 apply. In addition, the following information shall be provided in the instruction leaflet supplied with the luminaire, if applicable:
a) operating position, if not universal;
b) weight and overall dimensions of the floodlight;
c) maximum projected area of the floodlight;.
d) limitation of use indoors and/or outdoor;
5.6 Construction
The provisions of Section 4 of lEO 60598-1 apply together with the requirements of 5.6.1 to 5.6.8.
5.6.1 Floodlights for use outdoors shall have protection against the ingress of moisture at least equivalent to IPX3.
5.6.2 Lampholder brackets and lamp supports where used shall withstand normal usage throughout the life of the floodlight. They shall accept and retain lamps which are within the dimensional tolerances stated in the appropriate lEO publication where applicable, and locate the lamp or lamps in the designed relationship to the optical control devices in the floodlight.
5.6.3 When provision is made for alternative sizes of lamps or light centre positions, the adjusting means shall be positive and firmly retained in the selected position.
5.6.4 Refractors, reflectors or any other light controlling components shall be so marked or constructed that they can be fitted or replaced only in the correct relationship to the light source.
5.6.5 The means for attaching the floodlight to its support shall be appropriate to the weight of the floodlight.
For floodlights for use above ground level outdoors, the connection shall withstand wind speeds of 150 km/h on the projected surface of the floodlight assembly without undue deflection.
Fixings which carry the weight of the floodlight and internal accessories shall be provided with appropriate means to prevent the dislodgement of any part of the floodlight by vibration, either in service or during maintenance.
Parts of floodlights for mounting heights of 3 m or higher which are fixed other than with at least two devices, for example, screws or equivalent means of sufficient strength, shall have such extra protection as to prevent those parts falling and endangering persons, animals and surroundings, if a fixing device fails under normal conditions. The points of attachment which allow the floodlight to rotate and which are tested below are excluded from the requirements of this paragraph.
Compliance shall be checked by inspection and, for floodlights for use above ground level outdoors, by the additional following test.
The floodlight is mounted with its largest projected area as viewed in elevation lying in the horizontal plane, and with the means of attachment secured in accordance with the manufacturer’s recommendations.AS NZS 60598.2.5 pdf download.