AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
AS NZS 4859.1:2018
AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
AS NZS 2442.2:2021
AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
AS NZS IEC 60331.2:2021
AS NZS IEC 60331.2:2021 pdf free.Tests for electric cables under fire conditions 一Circuit integrity. 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: • IEC Electropedia: available at http://www.electropedia.org/ • ISO Online browsing platform: available at http://www.iso.org/obp 3.1 circuit...
AS 1141.19:2018
AS 1141.19:2018 pdf free.Methods for sampling and testing aggregates Method 19: Fine particle size distribution in road materials by sieving and decantation. NOTE 1 Complete dispersion in the initial pours is not essential, provided that continual dilution with ammonia is carried out. The addition of ammonia and stirring will in most cases complete dispersion eventually. With heavy clays, the first...
AS NZS 62233:2021
AS NZS 62233:2021 pdf free.Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure (IEC 62233:2005 (ED. 1.0) MOD). 5.3 Measuring distances, positions and operating mode The measuring distances, sensor locations and operating conditions are specified in Annex A. The configuration and mode of operation during measurement shall be noted in the test report....
AS 4485.2:2021
AS 4485.2:2021 pdf free.Security for healthcare facilities Part 2: Procedures guide. Many facilities process and store information on computers, or computer systems, as well as in hard copy form. When identifying information to be protected, it is important to look at both electronic (locally and remotely stored) and hard copy holdings. 3.4 Assessment of threats 3.4.1 Non-deliberate threats Not all...
AS 5246.1:2021
AS 5246.1:2021 pdf free.Cranes - Classification Part 1: General (ISO 4301-1:2016, MOD). 5.2 Use of classification for commercial specification The classification is applied by the purchaser and the manufacturer of a crane and/or load lifting attachments, between which agreement is necessary on the duty of the crane. The classification thus agreed is intended for contractual and technical reference purposes. It...
AS 4685.3:2021
AS 4685.3:2021 pdf free.Playground equipment and surfacing Part 3: Additional safety requirements and test methods for slides (EN 1176-3:2017, MOD). For attachment slides where the platform is used as the entire starting section, the requirements for protection against falling in EN 1176-1:2017, 4.2.4, apply. For free-standing slides, the guarding section shall have a height of at least that required for...
AS ISO 7240.24:2018
AS ISO 7240.24:2018 pdf free.Fire detection and alarm systems Part 24: Fire alarm loudspeakers. 5.1.2 Operating conditions for tests 5.1.2.1 Unless otherwise stated in a test procedure, the test specimen shall be a) set to its highest power setting, b) preconditioned in accordance with Annex A, and c) mounted in the acoustical environment as described in Annex A and as...