AS NZS 2588:2018 pdf free – Gypsum plasterboard AS pdf free download

AS NZS 2588:2018 pdf free – Gypsum plasterboard

AS NZS 2588:2018 pdf free.Gypsum plasterboard. 9.1.3 Edge hardness When tested in accordance with Appendix D, gypsum plasterboard shall have an edge hardness of not less than 45 N. NOTE The edge hardness test is used to ensure the gypsum plasterboard edge can resist crushing during handling and installation. 9.1.4 Nail pull resistance When tested in accordance with Appendix E,...
Download
AS ISO 7240.10:2018 pdf free – Point-type flame detectors AS pdf free download

AS ISO 7240.10:2018 pdf free – Point-type flame detectors

AS ISO 7240.10:2018 pdf free.Fire detection and alarm systems Part 10: Point-type flame detectors. 5.7 On-site sensitivity adjustment If there is provision for on-site sensitivity adjustment of the detector, then: a) for all settings at which the manufacturer claims compliance, the detector shall comply with the requirements of this part of ISO 7240 and shall achieve a classification corresponding to...
Download
AS 7240.22:2018 pdf free AS pdf free download

AS 7240.22:2018 pdf free

AS 7240.22:2018 pdf free.Fire detection and alarm systems Part 22: Smoke-detection equipment for ducts (ISO 7240-22:2017, MOD). 4.5 Manufacturer’s adjustments It shall not be possible to change the manufacturer’s settings except by special means (e.g. the use of a special code or tool) or by breaking or removing a seal. 4.6 On-site adjustment of response behaviour 4.6.1 If there is...
Download
AS IEC 60990:2018 pdf free – Methods of measurement of touch current and protective conductor current AS pdf free download

AS IEC 60990:2018 pdf free – Methods of measurement of touch current and protective conductor current

AS IEC 60990:2018 pdf free.Methods of measurement of touch current and protective conductor current. 4.2 Test transformer The use of a test transformer for isolation is optional. For maximum safety, a test transformer for isolation (T2 in Figure 2, T in Figure 6 to Figure 14) shall be used and the main protective earthing terminal of the EQUIPMENT under test...
Download
AS 80601.2.30:2018 pdf free AS pdf free download

AS 80601.2.30:2018 pdf free

AS 80601.2.30:2018 pdf free.Medical electrical equipment Part 2.30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers (IEC 80601-2- 30:2018, MOD). 201.1.3 Collateral standards Addition: This particular standard refers to those applicable collateral standards that are listed in Clause 2 of the general standard and Clause 201.2 of this particular standard. IEC 60601-1-2, IEC 60601-1-6, IEC...
Download
AS NZS 60598.2.5:2018 pdf free AS pdf free download

AS NZS 60598.2.5:2018 pdf free

AS NZS 60598.2.5:2018 pdf free. Luminaires Part 2.5: Particular requirements- Floodlights (IEC 60598-2-5:2015 (ED.3.0), MOD). 5.5 Marking The provisions of Section 3 of IEC 60598-1 apply. In addition, the following information shall be provided in the instruction leaflet supplied with the luminaire, if applicable: a) operating position, if not universal; b) weight and overall dimensions of the floodlight; c) maximum...
Download
AS 1141.34:2018 pdf free – Organic impurities other than sugar AS pdf free download

AS 1141.34:2018 pdf free – Organic impurities other than sugar

AS 1141.34:2018 pdf free.Methods for sampling and testing aggregates Method 34: Organic impurities other than sugar. 7 Reagents All reagents shall be of analytical grade. The following reagents are required: (a) Sodium hydroxide. (b) Tannic acid. (c) Ethanol. (d) Distilled or deionized water. 8 Test portion By coning and quartering or using sample dividers, take a test portion of approximately...
Download
AS NZS 1301.011:2018 pdf free – Klason lignin in wood and pulp AS pdf free download

AS NZS 1301.011:2018 pdf free – Klason lignin in wood and pulp

AS NZS 1301.011:2018 pdf free.Methods of test for pulp and paper Method 011: Klason lignin in wood and pulp. 6 PREPARATION OF TEST SPECIMEN The test specimen shall be prepared as follows: (a) Collect a representative sample of wood chips according to AS/NZS 1301.Ol3rp or a representative sample of pulp according to AS/NZS ISO 7213. (b) For wood, prepare the...
Download
AS 5218:2018 Acoustic performance of windows and doors AS pdf free download

AS 5218:2018 Acoustic performance of windows and doors

AS 5218:2018 pdf free.Acoustic performance of windows and doors—Methods of test. 3.6 Weighted sound reduction index (Re.) and spectrum adaptation terms (C, Cir) The single-number quantity resulting from a comparison of the values of measured sound reduction index (R) obtained using Equation 3.5 with reference values for one-third octave bands within the range 100 Hz to 3150 Hz, calculated in...
Download
AS 62053.61:2018 pdf download AS pdf free download

AS 62053.61:2018 pdf download

AS 62053.61:2018 pdf download.Electricity metering equipment (a.c.)- Particular requirements Part 61: Power consumption and voltage requirements (IEC 62053- 61:1998, MOD). 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of IEC 62053. At the time of publication, the editions indicated were valid. All normative documents are subject to revision,...
Download