BS EN ISO 21853:2020 pdf free.Kite boarding - Release system - Safety requirements and test methods. 4.4 Handling 4.4.1 General It shall be possible to trigger the main release system by a first single action. It shall be possible to trigger the disconnecting release system it by a second single action. The action for triggering shall be ergonomically and kinematically...
BS EN ISO 20418-3:2020 pdf free
BS EN ISO 20418-3:2020 pdf free.Textiles一Qualitative and quantitative proteomic analysis of some animal hair fibres. 8.1 Sampling The general requirement is that the test specimen shall be representative for the lot of material from which it is taken. The method to obtain a fibre test specimen differs depending on the sample form. The terms relating to sampling for the various...
BS EN ISO 17871:2020 pdf free
BS EN ISO 17871:2020 pdf free.Gas cylinders一Quick-release cylinder valves一Specification and type testing. Quick-release cylinder valves shall comply with all requirements of ISO 10297 unless this document expressly allows differing requirements or stipulates additional requirements. It is the responsibility of the manufacturer to classify the type of the quick-release cylinder valve according to the definitions in 3.2 (type A) or 3.3...
BS EN ISO 16610-29:2020 pdf free
BS EN ISO 16610-29:2020 pdf free.Geometrical product specifications (GPS)一Filtration. Wavelet analysis consists of decomposing a profile into a linear combination of wavelets ga,b(x), all generated from a single mother wavelet. This is similar to Fourier analysis, which decomposes a profile into a linear combination of sinewaves, but unlike Fourier analysis, wavelets are finite in both spatial and frequency domain. Therefore,...
BS EN ISO 16526-2:2020 pdf free
BS EN ISO 16526-2:2020 pdf free.Non-destructive testing - Measurement and evaluation of the X-ray tube voltage. The equipment to be used includes the following components, see figure 1:the X-ray system;a specified collimator;a specified filter;suitable dose meter or dose rate meter;a film for the prove of good collimation and dose meter or dose rate meter adjustment.used for documentation. Figure 3 shows...
BS EN ISO 16140-5:2020 pdf free
BS EN ISO 16140-5:2020 pdf free.Microbiology of the food chain一Method validation. The aim of the interlaboratory study is to compare the performance of the reference method to the alternative method in terms of the RLOD obtained by different laboratories. The results of the same set of samples, examined under reproducibility conditions, are compared with pre-set criteria for the acceptable difference...
BS EN ISO 9092:2019 pdf free
BS EN ISO 9092:2019 pdf free.Nonwovens - Vocabulary (ISO 9092:2019). nonwoven engineered (3.1.2) fibrous assembly, primarily planar, which has been given a designed level ofstructural integrity by physical and/or chemical means, excluding weaving, knitting or papermaking. engineered anything that benefited from an application of science to design, plan and manufacture products to utility specifications. fibrous assembly predetermined amount and arrangement...
BS EN ISO 8289-1:2020 pdf free
BS EN ISO 8289-1:2020 pdf free.Vitreous and porcelain enamels - Low-voltage test for detecting and locating defects. The test electrode for method A consists of a sponge made of plastic, cellulose or similar material. For rough scanning of large enamelled surfaces, test electrodes with an area of not greater than 100 cm2 shall be used. Any defects that are detected...
BS ISO 19161-1:2020 pdf free
BS ISO 19161-1:2020 pdf free.Geographic information - Geodetic references. The ITRS is defined jointly by the IAU and the IUGG It is the spatial three-dimensional part of a specific Geocentric Terrestrial Reference System (GTRS) for which the orientation is maintained in continuity with past international agreements (the so-called BIH orientation). Since 1988 both the monitoring of the definition of ITRS...
BS ISO 6721-4:2019 pdf free
BS ISO 6721-4:2019 pdf free.Plastics一Determination of dynamic mechanical properties. Test specimens of rectangular cross-section are recommended to facilitate load introduction. The width and thickness shall not vary along the specimen length by more than 3 % of the mean value. It is also recommended that the length of the specimen between the clamps be longer than six times the specimen...