AS NZS 2885.6:2018 pdf free.Pipelines- Gas and liquid petroleum Part 6: Pipeline safety management. 1.5.3 Documentation 1.5.3.1 General The SAFETY MANAGEMENT PROCESS shall be documented with sufficient detail so that independent reviewers or future users can make an informed assessment of the integrity of the process and its outcomes, including the basis for the identification of THREATS and the reasoning...
AS 62053.23:2018 pdf free – Static meters for reactive energy
AS 62053.23:2018 pdf free.Electricity metering equipment (ac)- Particular requirements Part 23: Static meters for reactive energy (classes 2 and 3) (IEC 62053-23:2016 (ED.1.1) MOD). 7.2 Influence of short-time overcurrents Short-time overcurrents shall not damage the meter. The meter shall perform correctly when back to its initial working condition and the variation of error shall not exceed the values shown in...
AS NZS 1577:2018 pdf free – Scaffold decking components
AS NZS 1577:2018 pdf free.Scaffold decking components. 1.4.4 I)eck infihl A plank or prefabricated platform less than 220 mm wide used to complete a platform when planks or prefabricated platforms do not modulate to suit the width of a scaffold bay. 1.4.5 Decking component A discrete component intended to be used to form a platform within a scaffold. NOTE: Types...
AS NZS 2588:2018 pdf free – Gypsum plasterboard
AS NZS 2588:2018 pdf free.Gypsum plasterboard. 9.1.3 Edge hardness When tested in accordance with Appendix D, gypsum plasterboard shall have an edge hardness of not less than 45 N. NOTE The edge hardness test is used to ensure the gypsum plasterboard edge can resist crushing during handling and installation. 9.1.4 Nail pull resistance When tested in accordance with Appendix E,...
AS ISO 7240.10:2018 pdf free – Point-type flame detectors
AS ISO 7240.10:2018 pdf free.Fire detection and alarm systems Part 10: Point-type flame detectors. 5.7 On-site sensitivity adjustment If there is provision for on-site sensitivity adjustment of the detector, then: a) for all settings at which the manufacturer claims compliance, the detector shall comply with the requirements of this part of ISO 7240 and shall achieve a classification corresponding to...
AS 7240.22:2018 pdf free
AS 7240.22:2018 pdf free.Fire detection and alarm systems Part 22: Smoke-detection equipment for ducts (ISO 7240-22:2017, MOD). 4.5 Manufacturer’s adjustments It shall not be possible to change the manufacturer’s settings except by special means (e.g. the use of a special code or tool) or by breaking or removing a seal. 4.6 On-site adjustment of response behaviour 4.6.1 If there is...
AS IEC 60990:2018 pdf free – Methods of measurement of touch current and protective conductor current
AS IEC 60990:2018 pdf free.Methods of measurement of touch current and protective conductor current. 4.2 Test transformer The use of a test transformer for isolation is optional. For maximum safety, a test transformer for isolation (T2 in Figure 2, T in Figure 6 to Figure 14) shall be used and the main protective earthing terminal of the EQUIPMENT under test...
AS 80601.2.30:2018 pdf free
AS 80601.2.30:2018 pdf free.Medical electrical equipment Part 2.30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers (IEC 80601-2- 30:2018, MOD). 201.1.3 Collateral standards Addition: This particular standard refers to those applicable collateral standards that are listed in Clause 2 of the general standard and Clause 201.2 of this particular standard. IEC 60601-1-2, IEC 60601-1-6, IEC...
AS NZS 60598.2.5:2018 pdf free
AS NZS 60598.2.5:2018 pdf free. Luminaires Part 2.5: Particular requirements- Floodlights (IEC 60598-2-5:2015 (ED.3.0), MOD). 5.5 Marking The provisions of Section 3 of IEC 60598-1 apply. In addition, the following information shall be provided in the instruction leaflet supplied with the luminaire, if applicable: a) operating position, if not universal; b) weight and overall dimensions of the floodlight; c) maximum...
AS 1141.34:2018 pdf free – Organic impurities other than sugar
AS 1141.34:2018 pdf free.Methods for sampling and testing aggregates Method 34: Organic impurities other than sugar. 7 Reagents All reagents shall be of analytical grade. The following reagents are required: (a) Sodium hydroxide. (b) Tannic acid. (c) Ethanol. (d) Distilled or deionized water. 8 Test portion By coning and quartering or using sample dividers, take a test portion of approximately...