AS NZS 60598.2.20:2018 pdf free.Luminaires Part 2.20: Particular requirements- Lighting chains (IEC 60598-2-20:2014, MOD). 20.7.3 Terminal blocks Clause 4.6 of Section 4 of IEC 60598-1 referring to terminal blocks does not apply. 20.7.4 Terminals and supply connections Clause 4.7 of Section 4 of IEC 60598-1 referring to terminals and supply connections applies together with the following requirement. Interconnecting connectors for...
AS NZS ISO 10006:2018 pdf free – Quality management—Guidelines for quality management in projects
AS NZS ISO 10006:2018 pdf free.Quality management—Guidelines for quality management in projects. LSUURCE: ISU 9(JUU:Z(J15, 32.5, moditied — Note 3 to entry has been added.> 4 Quality management systems in projects 4.1 Context and characteristics of the project 4.1.1 General Both the project organization and the originating organization (see 4.1.2) should consider the context in which their project quality management...
AS 1530.8.2:2018 Tests on elements of construction for buildings exposed to simulated bushfire attack—Large flaming sources
AS 1530.8.2:2018 pdf free.Methods for fire tests on building materials, components and structures Part 8.2: Tests on elements of construction for buildings exposed to simulated bushfire attack—Large flaming sources. 13 GENERAL TEST PROCEDURE 13.1 General This Clause (13) sets out the general test procedure. The test shall be performed in accordance with the requirements of AS 1530.4, except as varied...
AS 62054.21:2018 pdf free
AS 62054.21:2018 pdf free.Electricity metering (AC)-Tariff and load control Part 21: Particular requirements for time switches (IEC 62054-21:2017 (ED.1.1), MOD). 7.5 Functional requirements and tests — accuracy 7.5.1 Time setting and programming 7.5.1.1 Time switches with mechanical analogue dials On a day dial, it shall be possible to set the time with an accuracy better than ±7,5 mm. It shall...
AS 3583.6:2018 pdf free – Determination of relative water requirement and strength index
AS 3583.6:2018 pdf free.Methods of test for supplementary cementitious materials Method 6: Determination of relative water requirement and strength index. 3 DEFINITIONS For the purpose of this Standard the definitions given below apply. 3.1 Control mortar A mortar prepared using a selected General Purpose cement without addition of supplementary cementitious material. 3.2 Test mortar A mortar prepared using a mixture...
AS 62054.11:2018 pdf download
AS 62054.11:2018 pdf download.Electricity metering equipment (a.c.)—Tariff and load control Part 11: Particular requirements for electronic ripple control receivers (IEC 62054-11:2004 (ED.1.1), MOD). If the bursts are applied while the receiver is in a quiescent state, it shall be verified that the receiver does not start as an effect of the bursts. For this purpose, 3 s after the bursts...
AS NZS 60335.2.82:2018 pdf free – Particular requirements for amusement machines and personal service machines
AS NZS 60335.2.82:2018 pdf free.Household and similar electrical appliances- Safety Part 2.82: Particular requirements for amusement machines and personal service machines. 4 General requirement This clause of Part 1 is applicable. 5 General conditions for the tests This clause of Part us applicable except as follows. 5.6 Replacement: Controls or switching devices in the user area are adjusted to the...
AS NZS 2885.0:2018 pdf free
AS NZS 2885.0:2018 pdf free.Pipelines- Gas and liquid petroleum Part 0: General requirements. 13 Basis of the AS(/NZS) 2885 series The objective of the AS(/NZS) 2885 series is to provide requirements for the safe design, construction, operation and maintenance of PIPELINE SYSTEMS that carry petroleum fluids. The AS(/NZS) 2885 series is a single and sufficient technical standard that provides an...
AS 7240.12:2018 pdf free – Line type smoke detectors using a transmitted optical beam
AS 7240.12:2018 pdf free.Fire detection and alarm systems Part 12: Line type smoke detectors using a transmitted optical beam. 4.4.2 If there are cables connecting separate parts of the detector, then a means shall be provided for a remote monitoring system (e.g. the fire detection control and indicating equipment) to detect a short or open circuit on those cables, in...
AS NZS 3733:2018 Textile floor coverings—Cleaning ma intenance of res idential and commercial carpeting
AS NZS 3733:2018 pdf free.Textile floor coverings—Cleaning ma intenance of res idential and commercial carpeting. 2.1 PLANNING A MAINTENANCE PROGRAM A maintenance program should be established at the time of the development and completion of the textile floor covering specification. Just as specifications have to be concerned with traffic volume and soiling rates, so too does the maintenance program. For...