SAE AS 5276-1:2019 pdf free.Performance Standard for Child Restraint Systems in Transport Category Airplanes. 2.5 Compatibility of a CRS to Size of Child Occupant: The CRS and its integral restraints shall be designed to be compatible with accepted classification standards, as indicated in 2.3 and 2.4, for the protection of children under high dynamic loads. a. Any child with a...
AS NZS 62841.2.10:2018 pdf free – Particular requirements for hand-held drills mixers
AS NZS 62841.2.10:2018 pdf free.Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery- Safety Part 2.10: Particular requirements for hand-held drills mixers. 19.6 This subclause is not applicable. 19.101 For mixers with more than one spindle, the spindles shall be adequately spaced in order to reduce the risk of entanglement. The minimal clearance c between rotating parts in...
AS 1603.13:2018 pdf download – Duct sampling smoke detectors
AS 1603.13:2018 pdf download.Automatic fire detection and alarm systems Part 13: Duct sampling smoke detectors. 3.2 Electrical requirements 3.2.1 Electrical safety Where the maximum working voltage exceeds extra-low voltage (ELy), the DSE shall conform with the appropriate requirements of AS/NZS 3100. 3.3 Connecting facilities The means of connection shall not permit disconnection of the DSE or its associated detector without...
AS ISO 22915.1:2018 pdf free
AS ISO 22915.1:2018 pdf free.Industrial trucks—Verification of stability Part 1: General. 4 Stability tests for trucks 4.1 Test procedure Truck stability shall be verified by means of one of the procedures described below. The truck is considered stable if it passes all tests without tip-over or meets the requirements by calculation. When comparing calculated and test values, the test values...
AS 4688.1:2018 pdf free – Safety and general requirements
AS 4688.1:2018 pdf free.Furniture—Fixed height chairs Part 1: Safety and general requirements. 5.2 Corners and edges The following requirements apply: (a) There shall be no sharp edges accessible to the user. (b) The ends of tubular components shall be capped or otherwise closed and finished smoothly. (c) All contact points with the floor shall be designed to militate against scratching....
AS 1141.54:2018 pdf free – Foreign material in crushed recycled concrete for use in pavements
AS 1141.54:2018 pdf free.Methods for sampling and testing aggregates Method 54: Foreign material in crushed recycled concrete for use in pavements. 4 TYPES OF FOREIGN MATERIAL Foreign material is categorized as follows: (a) Type I or high density material such as asphalt, breccia, brick, ceramics glass, metal, sandstone, shale or slag (not blast furnace slag). (b) Type II or lowdensity...
AS 1670.3:2018 pdf free – Part 3: Fire alarm monitoring
AS 1670.3:2018 pdf free.Fire detection, warning, control and intercom systems- -System design, installation and commissioning Part 3: Fire alarm monitoring. 3.1 GENERAL Equipment shall be installed in locations that will not prejudice its performance and reliability. Access for servicing all equipment shall be provided. Where special installation arrangements are required. the recommendations in the equipment documentation for that application should...
AS 62053.24:2018 pdf free
AS 62053.24:2018 pdf free.Electricity metering equipment (ac)- Particular requirements Part 24: Static meters for reactive energy at fundamental frequency (classes 0.5S, 1 S and 1). 7.3 Influence of short-time overcurrents Short-time overcurrents shall not damage the meter. The meter shall perform correctly when back to its initial working condition and the variation of error shall not exceed the values shown...
AS NZS 1680.4:2017 Interior and workplace lighting Part 4: Maintenance of electric lighting systems
AS NZS 1680.4:2017 pdf free.Interior and workplace lighting Part 4: Maintenance of electric lighting systems. 2.1 GENERAL All lighting schemes within a building will deteriorate progressively from the time they are installed. The losses are due to the accumulation of dust and dirt on all exposed surfaces of lamps, luminaires and room surfaces—reducing the transparency or reflecting power—and to the...
AS 1603.11:2018
AS 1603.11:2018 pdf free.Automatic fire detection and alarm systems Part 11: Visual warning devices. 2.3 Luminance requirements for LED matrix, fixed message type VWD 2.3.1 Mean luminance The mean luminance for LED matrix VWD shall be not less than 180 cd/rn2. 2.3.2 Uniformity The ratio of maximum luminance to minimum luminance across the VWD shall be not less than 100:1...