AS 7240.4:2018 pdf free AS pdf free download

AS 7240.4:2018 pdf free

AS 7240.4:2018 pdf free.Fire detection and alarm systems Part 4: Power supply equipment (ISO 7240-4:2017, MOD). 5.3 Power sources 5.3.1 General 5.3.1.1 There shall be at least two power sources for the power supply of the FDAS: the main power source and the standby power source. 5.3.1.2 Each power source, on its own, shall be capable of meeting the PSE...
Download
AS NZS 60598.2.5:2002 pdf free AS pdf free download

AS NZS 60598.2.5:2002 pdf free

AS NZS 60598.2.5:2002 pdf free.Luminaires Part 2.5: Particular requirements- Floodlights. 5.6.1 Floodlights for use outdoors shall have protection against the ingress of moisture at least equivalent to IPX3. 5.6.2 Lampholder brackets and lamp supports where used shall withstand normal usage throughout the life of the floodlight. They shall accept and retain lamps which are within the dimensional tolerances stated in...
Download
AS 22915.12:2018 pdf free AS pdf free download

AS 22915.12:2018 pdf free

AS 22915.12:2018 pdf free.Industrial trucks—Verification of stability Part 12: Industrial variable-reach trucks handling freight containers of 6 m (20 ft) length and longer (ISO 22915- 12:2015, MOD). 3.1 industrial variable-reach truck handling freight container counterbalanced lift truck with an articulating boom, telescopic or not, non-slewing, as defined in ISO 5053:1987, 4.13.2.2.2, used especially for handling freight containers of 6 m...
Download
AS 1289.6.4.2:2016 pdf free – Determination of compressive strength of a soil AS pdf free download

AS 1289.6.4.2:2016 pdf free – Determination of compressive strength of a soil

AS 1289.6.4.2:2016 pdf free.Methods of testing soils for engineering purposes Method 6. 4.2: Soil strength and consolidation tests—Determination of compressive strength of a soil—Compressive strength of a saturated specimen tested in undrained triaxial compression with measurement of pore water pressure. (i) Apparatus for applying back pressure to the specimen to an accuracy of ±2 kPa or ± 0.5%, whichever is...
Download
AS NZS 1260:2017 pdf free – PVC-U pipes and fittings for drain, waste and vent applications AS pdf free download

AS NZS 1260:2017 pdf free – PVC-U pipes and fittings for drain, waste and vent applications

AS NZS 1260:2017 pdf free.PVC-U pipes and fittings for drain, waste and vent applications. 1.4 DEFINITIONS For the purpose of this Standard, the definitions given in AS 3500.0 and those below apply. 1.4.1 Best environmental practice PVC pipes and fittings Pipes or fittings produced by a manufacturer meeting both of the requirements of the credit criteria prescribed in Appendix C...
Download
AS 1163:2016 pdf free AS pdf free download

AS 1163:2016 pdf free

AS 1163:2016 pdf free.Cold-formed structural steel hollow sections. 3.5 Cold-rolled and annealed coil Flat product manufactured by cold-rolling and subsequent annealing of hot-rolled coil. Cold-rolled coil is hot-rolled coil that has been subjected to a cold-rolling reduction of more than 15%. The coil shall have a subcritical annealing cycle that recrystallises the structure and forms new ferrite grains. The resulting...
Download
AS 3894.10:2002 Site testing of protective coatings Method 3: Determination of dry film thickness AS pdf free download

AS 3894.10:2002 Site testing of protective coatings Method 3: Determination of dry film thickness

AS 3894.10:2002 pdf free.Site testing of protective coatings Method 3: Determination of dry film thickness. 3A Secondary standards Standards that are referenced to the primary standards and are used in the field. 4 TEST METHODS The coating film thickness may be measured using magnetic pull-off gauges (see clause 9), or by eddy current or magneti.c induction type instruments (see clause...
Download
AS 1012.20.2:2016 pdf free – Determination of water-soluble chloride in aggregates and hardened concrete AS pdf free download

AS 1012.20.2:2016 pdf free – Determination of water-soluble chloride in aggregates and hardened concrete

AS 1012.20.2:2016 pdf free.Methods of testing concrete Method 20.2: Determination of water-soluble chloride in aggregates and hardened concrete. 5 REAGENTS AND STANDARD SOLUTIONS Analytical quality reagents shall be used. The following are required: (a) Distilled water Distilled water shall be used for the preparation of all reagents and standard solutions. (b) Nitric acid Prepare a 1:4 diluted solution of concentrated...
Download
AS NZS 5263.1.7:2020 pdf download – Domestic outdoor gas cooking appliances AS pdf free download

AS NZS 5263.1.7:2020 pdf download – Domestic outdoor gas cooking appliances

AS NZS 5263.1.7:2020 pdf download.Gas appliances Part 1.7: Domestic outdoor gas cooking appliances. 2.2.106 Prevention of separation of barbecues from detachable trolleys For an appliance supported by a detachable trolley, means shall be provided to prevent inadvertent separation of the appliance from the trolley. 2.2.107 Adequacy of means of support Appliances having more than two wheels shall be provided with...
Download
AS NZS IEC 60332.1.1:2017 pdf free download Tests on electric and optical fibre cables under fire conditions Part 1.1: Test for vertical flame propagation for a single insulated wire or cable- Apparatus AS pdf free download

AS NZS IEC 60332.1.1:2017 pdf free download Tests on electric and optical fibre cables under fire conditions Part 1.1: Test for vertical flame propagation for a single insulated wire or cable- Apparatus

AS NZS IEC 60332.1.1:2017 pdf free download. Tests on electric and optical fibre cables under fire conditions Part 1.1: Test for vertical flame propagation for a single insulated wire or cable- Apparatus. 5.4 Flame application Safety warning Precautions shall be taken to safeguard personnel against the following when conducting tests: a) the risk of fire or explosion; b) the inhalation...
Download