AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
AS NZS 60598.2.5:2018 pdf free
AS NZS 60598.2.5:2018 pdf free. Luminaires Part 2.5: Particular requirements- Floodlights (IEC 60598-2-5:2015 (ED.3.0), MOD). 5.5 Marking The provisions of Section 3 of IEC 60598-1 apply. In addition, the following information shall be provided in the instruction leaflet supplied with the luminaire, if applicable: a) operating position, if not universal; b) weight and overall dimensions of the floodlight; c) maximum...
AS NZS 60598.2.21:2018 pdf free – Particular requirements—Rope lights
AS NZS 60598.2.21:2018 pdf free.Luminaires Part 2.21: Particular requirements—Rope lights (IEC 60598-2-21:2014, MOD). 21.7 Construction 21.7.1 General The provisions of Section 4 of IEC 60598-1 apply together with the requirements of 21.7.2 to 21.7.5. 21.7.2 Terminal blocks Clause 4.6 of Section 4 of IEC 60598-1 referring to terminal block does not apply. 21.7.3 Terminals and supply connections Clause 4.7 of...
AS NZS 60598.2.20:2018 pdf free – Particular requirements- Lighting chains
AS NZS 60598.2.20:2018 pdf free.Luminaires Part 2.20: Particular requirements- Lighting chains (IEC 60598-2-20:2014, MOD). 20.7.3 Terminal blocks Clause 4.6 of Section 4 of IEC 60598-1 referring to terminal blocks does not apply. 20.7.4 Terminals and supply connections Clause 4.7 of Section 4 of IEC 60598-1 referring to terminals and supply connections applies together with the following requirement. Interconnecting connectors for...
AS NZS 60598.2.5:2002 pdf free
AS NZS 60598.2.5:2002 pdf free.Luminaires Part 2.5: Particular requirements- Floodlights. 5.6.1 Floodlights for use outdoors shall have protection against the ingress of moisture at least equivalent to IPX3. 5.6.2 Lampholder brackets and lamp supports where used shall withstand normal usage throughout the life of the floodlight. They shall accept and retain lamps which are within the dimensional tolerances stated in...
AS NZS 60598.1:2017 Luminaires Part 1: General requirements and tests
AS NZS 60598.1:2017 pdf free download.Luminaires Part 1: General requirements and tests. Where the requirements of any of the sections of Part 1 are referred to in the parts of IEC 60598-2 by the phrase “The requirements of section... of IEC 60598-1 apply”, this phrase is to be interpreted as meaning that all the requirements of that section of Part...