5 General test requirements
Unless otherwise specified, the values stated in this part of Iso 16900 are expressed as nominal values. Except for temperature limits, values which are not stated as maxima or minima shall be subject to a tolerance of ±5 %. Unless otherwise specified, the ambient conditions for testing shall be between 16 °C and 32 °C and (50 ± 30) % relative humidity. Any temperature limits specified shall be subject to an accuracy of ±1 °C.
6 Principle
This test quantifies the field of vision of a respiratory protective device (RPD) by measuring the functional visual field score. The RPD is mounted on a headform containing small light sources instead of eyes. The light from the light sources is projected onto the apertometer, creating a light area outlined by a shadow that follows the periphery of the visual obstruction of the RPD system. The light area represents the visual field, or peripheral isopter. A quantitative value for the visual field score is obtained by comparing the peripheral isopter with a visual field score defined for different segments of the unrestricted field of vision.
7 Apparatus
The following apparatus are used for determining the visual field score.
a) Headforms: see Annex B.
b) Apertometer: see Figure 1.
c) Visual field score plotting chart: See Figure 2.
8 Device preparation
Prepare the RPD to the ready for use condition in accordance with the manufacturer’s instructions for use.
This involves attaching any accessories that may obscure vision, such as demand valve or filter(s), or filter
simulator (ISO 1690 0-5) for devices containing the thread connection in accordance with ISO 1742 0-3.
The headform size(s) appropriate to the size of RPD being tested shall be selected for the test.
8.1 Mounting the device
Mount the RPD on the selected headform in accordance with the manufacturer’s donning instructions. Position the RPD symmetrically on the headform. If the RPD has wearer-adjustable head harness straps, tighten the straps to the extent that would be expected when wearing the device as specified by the manufacturer.
NOTE If necessary, apply a friction reducing material talcum powder to the headform to allow the RPD to slide more easily over the headform surface during adjustment.
Position the head form correctly within the apertometer (see Figure 1).
The head form is positioned correctly when the centre of the light source of the illuminated eyes are aligned with the 90 degree meridians on the dome, symmetrically about the centre line of the dome and the horizontal axis of the headform is coincident with the axis of the apertometer.AS ISO 16900.11 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information