AS NZS 2442.1:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 1: Methods for measuring performance, energy and water consumption.
3.1 General
The specified measurements shall be conducted under the conditions specified in Clauses 3.2 to 3.7
and Appendix F.
3.2 Condition and installation of dryer
The measurements shall be carried out on a dryer installed and used in accordance with the manufacturer’s instructions. Where manufacturer’s instructions are in conflict with the specifications of this Standard, the methods specified in this Standard shall be used. Before measurements are commenced, the dryer shall be checked to see that it has no defects which could affect the operation of the unit.
3.3 Lint trap
Where the dryer is equipped with a lint trap, it shall be thoroughly cleaned before each test run.
3.4 Exhaust
3.4.1 General
In all cases, the airflow around the dryer shall be unobstructed. This condition shall be met by maintaining a minimum 100 mm clearance from adjacent walls or partitions at the sides and back of the dryer.
3.4.2 Dryers requiring an exhaust duct
Where the dryer needs to be operated with a duct or deflector fitted, as intended by the manufacturer, the tests shall be carried out with this item fitted in accordance with the manufacturer’s instructions.
3.4.3 Dryers with an optional exhaust duct
Where a dryer is designed to operate with an optional exhaust duct, the dryer shall be tested without the duct fitted, in accordance with the manufacturer’s instructions for operation without a duct.
3.4.4 Dryers without an exhaust duct
Where a dryer is designed solely to operate without an exhaust duct, the test shall be carried out in accordance with the manufacturer’s instructions.
3.4.5 Recording of results
Details of the exhaust duct or deflector fitted, if any, shall be recorded on the test report.
3.5 Program settings
Except where stated otherwise in Clause D.2.4, the following shall apply:
(a) Manual and timer dryers shall be set on maximum temperature.
(b) Autosensing dryers shall be set on the chosen program, i.e. the program under test.
(c) Where the drying temperature can be chosen independently of the program on an autosensing dryer, it shall be set to the maximum.AS NZS 2442.1 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information