AS NZS 2588:2018 pdf free – Gypsum plasterboard

09-07 comment

AS NZS 2588:2018 pdf free.Gypsum plasterboard.
9.1.3 Edge hardness When tested in accordance with Appendix D, gypsum plasterboard shall have an edge hardness of not less than 45 N. NOTE The edge hardness test is used to ensure the gypsum plasterboard edge can resist crushing during handling and installation. 9.1.4 Nail pull resistance When tested in accordance with Appendix E, gypsum plasterboard shall have minimum nail pull resistance appropriate to its intended use as shown in Table 2. NOTE The nail pull test is used to ensure the gypsum plasterboard has sufficient strength to resist fastener pull through due to in-service loads.
9.1.5 Bond strength When tested in accordance with Appendix E, the bond strength of the test specimen in tension shall be not less than 250 N after 24 h drying , NOTE This test is to assess the adequacy of the gypsum plasterboard back paper lining bond to the gypsum core and the inter-ply or cohesive bond strength of the back paper liner. This is particularly important where gypsum plasterboard is applied to a substrate with a combination of mechanical fasteners and adhesive system in accordance with AS/NZS 2589.
9.2 Water-resistant grade gypsum plasterboard
9.2.1 General
In addition to the requirements of Clause 9i., water-resistant grade gypsum plasterboard shall conform with Clauses 9.2.2 and 9.2.3.
9.2.2 Water resistance
When tested in accordance with Appendix H. the plasterboard specimens shall have an average water absorption of not more than 5 % weight after two hours of testing.
9.23 Surface water resistance
When tested in accordance with Appendix I, the average difference between the dry and wet weights of
the specimens shall not exceed 1.6 g after two hours of testing.
10 Marking
Each sheet of gypsum plasterboard shall be clearly marked with the following particulars:
(a) The manufacturer’s name or trademark.
(b) Nominal thickness.
(c) Width.
(d) Type of edge.
Product name or classification.
The grade of plasterboard shall be displayed on the back 01 the sheet at no greater than 1.2 m intervals. This grading shall be displayed by the use of registered marks, trademarks or other means that clearly classifies the plasterboard.
NOTE A date and time mark is commonly also applied to facilitate production control.AS NZS 2588 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information