AS NZS 4234:2021

09-08 comment

AS NZS 4234:2021 pdf free.Heated water systems一Calculation of energy consumption一Parameters and outcomes for software simulations.
Detail heat pump operating times [e.g. continuous, off-peak (10 pm to 7 am), extended off-peak (10 pm to 5 pm)], other time control or other strategy (provide separate description of control logic if strategy is not simple time control).
Detail supplementary heating times [e.g. continuous, off-peak (10 pm to 7 am), extended off-peak (10 pm to 5 pm)], other time control or other strategy (provide separate description of control logic if strategy is not simple time control).
Heat pump is on continuous power feed. The HP will operate when the control temperature falls below the set temperature (within the deadband limits) and the ambient air is above the cold temperature cut-off.
Supplementary boosting is on continuous feed. The supplementary booster will operate if the thermostat senses low temperature and is within deadband limits AND the ambient air is below the cold temperature cut-out.
HP set temperature is 60 °C with a DB of 8 and the HP control sensor is at 46 % of the tankvolume. If the HPis not operative then the boost element is operated and has 46 % of the tank volume and the same set temperature. These requirements satisfy legionella sanitation as specified in AS 3498.
Heat pump is on continuous power feed. The HP will operate when the control temperature falls below the set temperature (within the deadband limits) and the ambient air is above the cold temperature cut-off.
Supplementary boosting is on continuous feed. The supplementary booster will operate if the thermostat senses low temperature and is within deadband limits AND the ambient air is below the cold temperature cut-out.
HP set temperature is 60 °C with a DB of 10 and the HP control sensor is at 48 % of the tank volume. If the HP is not operative, then the boost element is operated and has 45 % of the tank volume and a set temperature of 60 °C with a DB of 8. These requirements satisfy legionella sanitation specified in AS 3498.AS NZS 4234 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download