AS NZS 4782.1:2020 pdf free

09-01 comment

AS NZS 4782.1:2020 pdf free.Double-capped fluorescent lamps – Performance specifications Part 1: General (IEC 60081:1997+AMD1:2000 CSV (ED.5.1), MOD).
1.5.2 Caps
The dimensions of the caps on a finished lamp shall be in accordance with IEC 60061-1.
For lamps with G5 or G13 caps, both pins (excluding flanges) of the two caps of a finished lamp shall pass simultaneously, freely without binding, through parallel slots, suitably spaced longitudinally to receive the lamp. The slots shall each be 2,87 mm wide for G5 caps, and 3,05 mm wide for G13 caps.
For lamps with R17d caps, both cap bosses of a finished lamp shall pass simultaneously, freely without binding, through parallel slots, suitably spaced longitudinally to receive the lamp with the bottom of the slots against the boss ends. The slots shall each be 6,35 mm deep and 9,22 mm wide.
1.5.3 Dimensions
The dimensions of a lamp shall comply with the values specified on the relevant lamp data sheet.
1.5.4 Starting characteristics
A lamp shall start fully within the time specified on the relevant lamp data sheet and remain alight.
Conditions and method of test are given in Annex A.
1.5.5 Electrical and cathode characteristics
Lamps shall comply with the following requirements:
a) The initial reading of the voltage at the lamp terminals shall comply with the values specified on the relevant lamp data sheet.
NOTE 1 It may be expected that over the declared lifetime of the lamp, the lamp voltage may rise typically by 5 V to 10 V.
b) The initial reading of the power dissipated by a lamp shall not exceed the rated wattage, specified on the relevant lamp data sheet, by more than 5 % + 0,5 W.
NOTE 2 Cathode watts due to supplementary heating are not included in the rated lamp wattage unless otherwise stated on the lamp data sheet.
c) The combined resistance of the lead wires connected to an individual cathode for a lamp without internal starter shall not be higher than 0,3 2.
d) For a lamp having preheated cathodes for operation on a.c. mains frequencies starterless circuits, the initial reading of the resistance of each cathode shall be not less than the minimum value specified on the relevant lamp data sheet. These resistance values include lead wire resistance.
e) For a lamp having preheated cathodes for operation on high frequency, the initial reading of the resistance of each cathode shall comply with the values specified on the relevant lamp data sheet. These resistance values include lead wire resistance.
In addition, the average value of the resistance ratio Rh/Rc of the coils of 10 cathodes shall be in the range 4,75 ± 0,5. Rh is the resistance of the cathode when heated with the specified test current. Rc is the resistance of the cathode at a temperature of 25 °C ± 1 °C. Both resistance values shall exclude lead wire resistance. Conditions and method of test are given in Annex B. AS NZS 4782.1 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information