AS NZS 5263.1.7:2020 pdf free.Gas appliances Part 1.7: Domestic outdoor gas cooking appliances.
2.2.106 Prevention of separation of barbecues from detachable trolleys
For an appliance supported by a detachable trolley, means shall be provided to prevent inadvertent separation of the appliance from the trolley.
2.2.107 Adequacy of means of support
Appliances having more than two wheels shall be provided with means to prevent movement of the appliance when in use.
2.2.108 Smoker oven or outdoor oven — Prevention of inadvertent placement of utensils in a flame
Smoker ovens or outdoor ovens shall be designed so as to prevent the accidental placement of shelves, cooking utensils or wood chip containers in a position where they may be impinged upon by a burner flame.
2.2.109 Smoker oven or outdoor oven — Prevention of accidental removal of shelves Smoker oven or outdoor oven shelves shall not be capable of being accidentally removed.
2.2.110 Smoker oven or outdoor oven — Stability of shelves
Smoker oven or outdoor oven shelves shall be stable and horizontal when in position in the appliance.
2.2.111 Smoker oven or outdoor oven — Door stability
Smoker oven or outdoor oven doors shall be so constructed that, when fully open, they will remain in that position.
2.2.112 Smoker oven or outdoor oven — Provision of explosion relief for appliances with door locks
Positive door locks shall not be used unless adequate provision for explosion relief is made.
2.2.113 Smoker oven — Flame contact with smoker materials
The burner flames shall not come into direct contact with the smoker materials used (e.g. wood chips).
2.3 Materials
This Clause of AS/NZS 5263.0 applies.
2.4 Design for assembly and installation
This Clause of AS/NZS 5263.0 applies, except as modified below.
2.4.3 Gas inlet connection
Where the appliance is to be connected to consumer piping, the gas inlet connection shall —
(a) have a thread in accordance with AS ISO 7.1 or AS 1722.2;
NOTE See AS 3688 for guidance on the appropriate class of thread for various types of connection.
(b) have a quick connect device in accordance with AS 4627, Type 1 or Type 2; or (c) have an SAE flare if the appliance is intended for boats or caravans.AS NZS 5263.1.7 pdf download.