AS NZS 60335.2.11:2020 pdf free – Particular requirements for tumble dryers

09-01 comment

AS NZS 60335.2.11:2020 pdf free.Household and similar electrical appliances- Safety Part 2.11: Particular requirements for tumble dryers.
19.4 Replacement:
The appliance is operated under the conditions specified in Clause 11 but with dry textile material. Controls that limit the temperature during the test of Clause 11 and all self-resetting thermal cut-outs that protect the heating elements are short-circuited simultaneously. The test is terminated at the end of the maximum period allowed by a timer.
For condensation-type tumble dryers, the test is repeated, but with 75 % of the air outlet of the condenser blocked. The test is then carried out again with the air outlet fully blocked.
19.9 Addition:
The running overload test is carried out on appliances that have overload protective devices incorporating electronic circuits to protect the windings of the drum motor. However, the test is not carried out lithe protective device senses the winding temperature directly.
19.13 Addition:
The textile material shall not ignite and shall show no charring or glowing.
NOTE 101 Light-brown colouring of the textile material or slight emission of smoke is ignored.
19.101 The appliance is operated under the conditions specified in Clause 11 but with dry textile material and the drum belt removed. The duration of the test is 90 mm or for the maximum period allowed by a timer.
If air circulation is likely to be prevented due to a fault condition, the test is repeated but with the drum belt in position and with the air circulation stopped. Care shall to be taken to ensure that the textile material is tumbling properly by reducing the load if necessary.
If both these conditions are likely to occur simultaneously, the tests are combined.
19.102 Appliances that permit test probe C of IEC 61032 to gain access to spaces containing live parts located below holes in the drum are tested for short circuit conditions. The short circuit is applied at the most unfavourable place between live parts and between live parts and other metal parts, if such a short circuit can be made by a pin having a diameter of approximately 1 mm and any length up to 50 mm. The appliance is operated as specified in Clause 11 but with dry textile material.
19.103 There shall be no risk of fire due to textile material coming into contact with a lamp cover.
Compliance is checked by the following test.
Ten layers of cheesecloth are placed over the lamp cover. The appliance is supplied at rated voltage with the door open until steady conditions are established. The temperature rise of the cover shall not exceed 150 K.AS NZS 60335.2.11 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information