AS NZS 60598.2.21:2018 pdf free – Particular requirements—Rope lights

09-07 comment

AS NZS 60598.2.21:2018 pdf free.Luminaires Part 2.21: Particular requirements—Rope lights (IEC 60598-2-21:2014, MOD).
21.7 Construction
21.7.1 General
The provisions of Section 4 of IEC 60598-1 apply together with the requirements of 21.7.2 to 21.7.5.
21.7.2 Terminal blocks
Clause 4.6 of Section 4 of IEC 60598-1 referring to terminal block does not apply.
21.7.3 Terminals and supply connections
Clause 4.7 of Section 4 of IEC 60598-1 referring to terminals and supply connections applies
together with the following requirement.
Interconnecting connectors for rope lights shall, in addition, comply with the requirements and modifications given in Annex A
Compliance is checked by inspection and by carrying out the tests of this standard.
21.7.4 Control units
Control units and similar devices forming an integral part of the rope light shall be enclosed in non-flammable insulating material. In addition they shall be securely fixed to the rope light or the cable.
Compliance shall be checked by inspection and, for the non-flammability of the insulating material, by the tests of Clause 21.16.
Any electronic control device (e.g. flasher units) shall, in addition to the requirements of this standard, comply with the requirements of IEC 61347-2-11.
LED-drivers shall comply with the requirements of IEC 61347-2-13.
Compliance shall be checked by carrying out the relevant tests.
21.7.5 Mechanical strength
Rope lights shall have adequate mechanical strength.
Compliance is checked by the following tests:
a) For rigid rope lights, compliance is checked by subjecting the pipe to each of the following tests carried out in turn.
1) A pull of 60 N, the stress being applied to the ends of the pipe, 45 times without jerks, each time for 1 s.
2) A torque of 0,15 Nm, the stress being applied to the ends of the pipe in the most unfavorable direction (alternatively in cases of doubt) without jerks for 1 mm.
During and after the above test tests, the conductors shall not have moved noticeably in the terminals and the pipe shall not be damaged.
b) For flexible rope lights, compliance is checked by the tests of 1) and 2) above followed by the additional tests 3) and 4) below.AS NZS 60598.2.21 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information