AS NZS 61347.2.2:2020 pdf free

09-01 comment

AS NZS 61347.2.2:2020 pdf free.Lamp controlgear Part 2.2: Particular requirements for d.c. or a.c. supplied electronic step- down convertors for filament lamps.
5 General notes on tests
The requirements of Clause 5 of IEC 61347-1 apply, with the following additional requirement:
5.8 Number of specimens
The following number of specimens shall be submitted for testing:
— one unit for the tests of Clauses 6 to 12 and 15 to 20;
— one unit for the tests of Clause 14 (additional units or components, where necessary, may be required in consultation with the manufacturer).
Unless otherwise declared by the manufacturer, the tests are carried out with the length of the output wire or cable either 20 cm or 200 cm, choosing the most unfavourable condition. It is possible to use two twisted wires or cable HO3VV-. The cross section of the conductors shall be chosen according to the rated wattage and the current density shall not exceed 5 A/mm2 in normal use.
6 Classification
Convertors are classified according to the method of installation given in Clause 6 of IEC 61347-1 and according to:
— Protection against electric shock
• auto wound (autotransformer) convertors,
• separating convertors,
• SELV convertors.
7 Marking
7.1 Mandatory marking
Convertors, other than integral convertors, shall be clearly and durably marked, in accordance with the requirements of 7.2 of IEC 61347-1, with the following mandatory markings:
— items a), b), c), d), e), f), k), I), rn), s) and t) of 7.1 of IEC 61347-1, together with
— rated output voltage.
7.2 Information to be provided if applicable
In addition to the above mandatory markings, the following information, if applicable, shall be
given either on the convertor, or be made available in the manufacturer’s catalogue or similar:
— items h), i), j) and s) of 7.1 of IEC 61347-1 together with
— mention whether the convertor has mains-connected windings,
— a declaration of the allowed length of the output wire or cable, if it is not between 20 cm and 200 cm.
8 Protection against accidental contact with live parts
The requirements of Clause 10 of IEC 61347-1 apply.AS NZS 61347.2.2 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS 60598.2.17:2019 AS pdf free download

AS NZS 60598.2.17:2019

AS NZS 60598.2.17:2019 pdf free.Luminaires Part 2.17: Particular requirements—Luminaires for stage lighting, television and film studios (outdoor and indoor). 17.7.2 The luminaires for certain types of high-intensity discharge lamp, where an explosion risk is declared by the lamp manufacturer, shall incorporate a device to prevent immediate access to the lamp after switching-off or shall be marked in accordance with the...
Download
AS NZS 4859.1:2018 AS pdf free download

AS NZS 4859.1:2018

AS NZS 4859.1:2018 pdf free.Thermal insulation materials for buildings Part 1: General criteria and technical provisions. 2.1 GENERAL This Section provides performance criteria and technical provisions for materials to be used in the thermal insulation of buildings and building services. In addition to this Section the insulating material shall— (a) meet packaging and labelling requirements of Section 3; (b) where...
Download
AS NZS 2442.2:2021 AS pdf free download

AS NZS 2442.2:2021

AS NZS 2442.2:2021 pdf free.Performance of household electrical appliances一Rotary clothes dryers Part 2: Energy efficiency labelling requirements. Section 2 Test requirements, calculations and algorithms for the energy rating label 2.1 General This Section sets out the test requirements, equations and procedures br calculating values of the comparative energy consumption (CEC), and star rating, which appear on an energy rating label....
Download

LEAVE A REPLY

Anonymous netizen Fill in information