BS EN 12916:2019 pdf free.Petroleum products – Determination of aromatic hydrocarbon types in middle distillates – High performance liquid chromatography method with refractive index detection.
A known mass of sample is taken and a fixed volume of this sample is injected into a high performance liquid chromatograph fitted with a polar column. Diesel fuels with a concentration of FAME up to 30 % (V/V) and petroleum distillates need to be diluted with heptane (Procedure A). Paraffinic diesel fuels are injected neat (Procedure B). This column has little affinity for non-aromatic hydrocarbons, while exhibiting a strong selectivity for aromatic hydrocarbons. As a result of this selectivity, the aromatic hydrocarbons are separated from the non-aromatic hydrocarbons and into distinct bands according to their ring structure, i.e. MAH, DAH and T+AH compounds. The column is connected to a refractive index detector which detects the components as they elute from the column. The electronic signal from the detector is continually monitored by a data processor. The amplitudes of the signals from the aromatics in the sample are compared with those obtained from calibration standards in order to calculate the mass fraction of MAHs, DAHs and T+AHs in the sample. The sum of the DAHs and T+AHs mass fractions is reported as the mass fraction of POLY-AH, and the sum of the MAHs, DAHs and T+AHs mass fractions is reported as the mass fraction of total aromatic hydrocarbons.
When following Procedure A, the column may be backflushed after the aromatics have eluted from the column to allow any remaining components such as FAME to elute in a backflush peak. This will allow for a better cleaning of the column but care should be taken as it can affect the lifetime of the column.Equal and constant volumes of the calibration and sample solutions are injected into the chromatograph. Both manual and automatic sample injection systems, using either complete or partial filling of the sample loop, can meet these repeatability requirements when used correctly. When using the partial filling mode, it is recommended that the injection volume is less than half the total loop volume. For complete filling of the loop, best results are obtained by overfilling the loop at least six times.BS EN 12916 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
BS ISO 24081:2021 pdf download BS pdf free download

BS ISO 24081:2021 pdf download

BS ISO 24081:2021 pdf download.Ground cassava leaves (Isombe) — Specification. 1 Scope This document specifies requirements and methods of sampling and testing for ground cassava leaves, which are obtained from the processing of fresh cassava leaves (Manihot esculenta Crantz or Manihot glaziovii) intended for human consumption. 2 Normative references The following documents are referred to in the text in such...
Download

BS EN 1463‑2:2021

BS EN 1463‑2:2021 pdf download.Road marking materials — Retroreflecting road studs Part 2: Road test performance specifications. 4 Test sites and conditions 4.1 General Test sites shall be arranged at suitable locations that meet at least the requirements of 4.2 to 4.5. The test results will depend on the weather, traffic and road surface conditions. These shall all be described...
Download
BS ISO 3739‑2:2021 pdf download BS pdf free download

BS ISO 3739‑2:2021 pdf download

BS ISO 3739‑2:2021 pdf download.Industrial tyres and rims Part 2: Pneumatic tyres (metric series) on 5 degrees tapered or flat base rims — Load ratings. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited...
Download

LEAVE A REPLY

Anonymous netizen Fill in information