BS EN 131-6:2019 pdf free

06-07 comment

BS EN 131-6:2019 pdf free.Ladders.
4 Functional dimensions 4.1 General dimensions Dimensions are given in EN 131-1. 4.2 Specific dimensions For leaning telescopic ladders dimension l3 is not applicable providing l6, see 4.3, is fulilled. If l6 is not fulflled l3 shall begreater than 0,5 I5 and less than I5 + 15 mm measured along a line in the middle of the stiles. 4.3 Top rung clearance l6 The dimension l6 is the horizontal clearance between the top rung and any obstruction (specifically the wall) when the ladder is in its position of use. The dimension l6 is the horizontal distance between the top rung and the wall when measured with the ladder in its position of use at any angle between 65° and 75° (see Figure 1). This shall not be less than 35 mm and not more than 300 mm. The minimum clearance between the top rung and any obstruction shall be 35 mm in any case.5 Requirements 5.1 General requirements The drawings in this part of EN 131 are examples only and products do not need to correspond. However, dimensions are binding. For other requirements EN 131 -2:2010+ A2:2017, Clause 4 applies. 5.2 Distance between rungs/steps When the ladder is in its position of use the rungs/steps allowed to stand on shall always be equally spaced in accordance with EN 131-1:2015, 4.1.In the position of use the construction shall not allow different distances between the rungs/steps with a tolerance of +2 mm in the ascendable part of the ladder and ensure that the rung/step sections that are not extended shall be stacked at the top of the ladder. Manufacturer shall take all necessary precautions to prevent these distances been altered without manipulation and the use of tools. 5.3 Additional requirements for the top of leaning ladders The top of the ladder shall be designed in a way that a 2-point area of contact between the top of the ladder and a vertical plane can be ensured. 5.4 Locking of the rung/step sections The ladder shall be designed in way that all extended rung/step sections are locked when the ladder is in the position of use. Every rung/step section shall have a locking mechanism for each stile. With the ladder in position of use it shall be clearly visible to the user that all of the locking mechanisms are locked or unlocked. NOTE Visible indication can for example be a coloured area of a visible locking pin.BS EN 131-6 pdf download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
BS ISO 24081:2021 pdf download BS pdf free download

BS ISO 24081:2021 pdf download

BS ISO 24081:2021 pdf download.Ground cassava leaves (Isombe) — Specification. 1 Scope This document specifies requirements and methods of sampling and testing for ground cassava leaves, which are obtained from the processing of fresh cassava leaves (Manihot esculenta Crantz or Manihot glaziovii) intended for human consumption. 2 Normative references The following documents are referred to in the text in such...
Download

BS EN 1463‑2:2021

BS EN 1463‑2:2021 pdf download.Road marking materials — Retroreflecting road studs Part 2: Road test performance specifications. 4 Test sites and conditions 4.1 General Test sites shall be arranged at suitable locations that meet at least the requirements of 4.2 to 4.5. The test results will depend on the weather, traffic and road surface conditions. These shall all be described...
Download
BS ISO 3739‑2:2021 pdf download BS pdf free download

BS ISO 3739‑2:2021 pdf download

BS ISO 3739‑2:2021 pdf download.Industrial tyres and rims Part 2: Pneumatic tyres (metric series) on 5 degrees tapered or flat base rims — Load ratings. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited...
Download

LEAVE A REPLY

Anonymous netizen Fill in information