IEC 62922:2016 pdf free download

01-29 comment

IEC 62922:2016,Organic light emitting diode (OLED) panels for general lighting – Performance requirements.
IEC 62922:2016 specifies the performance requirements of OLED tiles and panels for use on DC supplies up to 120 V or AC supplies up to 50 V at 50 Hz or 60 Hz for indoor and similar general lighting purposes.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60050-845, International Electrotechnical Vocabulary. Lighting.
IEC 62868, Organic light emitting diode (OLED) panels for general lighting — Safety requirements.
IEC TR 62732, Three-digit code for designation of colour rendering and correlated colour temperature.
IEC TS 62972, General lighting — Organic light emitting diode (OLED) products and related equipment — Terms and definitions.
4 General statement and test conditions
4.1 General statement
The requirements of this document apply in addition to the requirements of IEC 62868.
The requirement applies for 95 % of the population (with a failure margin below 5 %, it is considered that the product passed the test).
It is understood that reference to an OLED panel also includes reference to OLED tiles in the requirements and tests of this document.
4.2 General test conditions
Unless otherwise specified, all measurements shall be made in a draught free room at a temperature of 25 °C with a tolerance of ±5 °C, a relative humidity of 65 % maximum and steady state operation of the OLED panel. The temperature shall be maintained within ±2 °C during the test. The temperature shall be measured in the integrating sphere or at the point within 1,5 m from the OLED panel.
The tests shall be conducted at the rated current or voltage unless otherwise specified in this document.
The test shall be made with the OLED panel in the horizontal mounting position with the surface emitting the largest fraction of luminous flux directed upwards, unless specified otherwise by the manufacturer. The mounting position shall be recorded in the documentation. If all surfaces are intended to emit the same luminous flux, the orientation is at the discretion of the test laboratory. The operating position shall be maintained during the entire test.
In the case of constant current operation: The test current, unless otherwise specified, shall be stable within ±0,5 % during the performance test of an OLED panel. The total harmonic content of the in put shall not exceed 3 %.
In the case of constant voltage operation: The test voltage, unless otherwise specified, shall be stable within ±0,05 % or 5 mV whichever is greater during the performance test of an OLED panel. The total harmonic content of the input shall not exceed 3 %. The tolerance of ±0,05 % is applicable for DC supplies only. The tolerance for AC supplies is under consideration. The test voltage shall be measured at the terminals of the OLED panel.IEC 62922:2016 pdf free download.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.
AS NZS IEC 61034.2:2017 pdf free Measurement of smoke density of cables burning under defined conditions Part 2: Test procedure and requirements AS pdf free download

AS NZS IEC 61034.2:2017 pdf free Measurement of smoke density of cables burning under defined conditions Part 2: Test procedure and requirements

AS NZS IEC 61034.2:2017 pdf free.Measurement of smoke density of cables burning under defined conditions Part 2: Test procedure and requirements. 5.2.2 Mounting of test sample The test sample shall remain in situ during the test as follows: — individual test pieces or bundles of test pieces shall be bound together at the ends, and at 300 mm from each...
Download

IEEE 1244.2-2000 pdf free download

IEEE 1244.2-2000 pdf free download.IEEE Standard for Media Management System (MMS) Session Security, Authentication, Initialization Protocol (SSAIP). Abstract: The syntax and semantics of the protocol messages that pass between the MMS client or MMS module and the MM are described. Since this protocol is only used in the context of the MMS, this standard cannot be understood without a thorough...
Download

BS IEC 61892-7:2007 pdf free

BS IEC 61892-7:2007 pdf free.Mobile and fixed offshore units - Electrical installations - Part7:Hazardous areas. IEC 61892 forms a series of International Standards intended to ensure safety in the design selection, installation, maintenance and use of electrical equipment for the generation storage, distribution and utilization of electrical energy for all purposes in offshore units which are used for the exploration...
Download

LEAVE A REPLY

Anonymous netizen Fill in information