IEEE C57.12.34-2004 pdf free

03-17 comment

IEEE C57.12.34-2004 – Standard for Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase DistributionTransformers, 2500 kVA and Smaller: High-Voltage, 34 500GrdY/19 920 Volts and Below; Low Voltage, 480 Volts and Below.
Abstract: Certain electrical, dimensional, and mechanical characteristics are set forth as well as certain safety features of three-phase, 60 Hz, mineral-oil-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 2500 kVA and smaller, with high-voltages of 34 500 GrdY 119 920 volts and below, and with low-voltages of 480 volts and below. This standard covers the connector, bushing and terminal arrangements for radial or loop feed systems. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.
Keywords: compartmental, connector arrangements, loop, pad mounted, radial, three phase, three-phase pad-mounted distribution transformers, transformer.
IEEE C57.12.34 is intended for use as a basis for determining performance. interchangeability, and safety of the equipment covered, and to assist in the proper selection of such equipment.
IEEE C57.12.34 covers certain electrical, dimensional, and mechanical characteristics and takes into consideration certain safety features of three-phase. 60 Hz, mineral-oil-immersed, self-cooled, pad- mounted, compartmental-type distribution transformers. These transformers are rated 2500 kVA and smaller, with high-voltages of 34 500 GrdY/ 19 920 volts and below, and with low-voltages of 480 volts and below. These transformers are generally used for step-down purposes from an underground primary cable supply. This standard covers the connector, bushing and terminal arrangements for radial or ioop feed systems. Either certain minimum dimensions (see Figures 1, 2, 3, 7, 8. and 11) or certain specific dimensions (see Figures 4, 5, 6, 9, 10, and 12) shall be specified. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.
NOTE—Refer to latest USA federal regulations concerning PCB contamination in transformers.
4.2 Voltage ratings
Voltage ratings shaH be in accordance with Table I of this standard,
4.3 Tap ratings
When specified, high-voltage taps shall be as given in Table 2 of this standard. The tap changer handle or the area next to the handle in the terminating compartment shall be marked indicating suitability for deenergized operation only.
5. Basic lightning impulse insulation levels
Basic lightning impulse insulation levels (BILs) shall be in accordance with Table 1, Table 3, and Table 4 of this standard.
6. Dielectric test levels
Dielectric test levels shall be in accordance with the distribution levels in Table 5 of IEEE Std C57.12.00.

Download It Now Download Here
ATTENTION: I REALLY NEED YOUR SUPPORT.THANKS A LOT.

IEEE 82-2002 pdf free

IEEE 82-2002 pdf free.IEEE Standard Test Procedure for Impulse Voltage Tests on Insulated Conductors. Insulated conductors in service are subjected to voltage surges from lightning. switching, and other sources. These surges vary widely in wave shape, magnitude. and frequency of occurrence. Laboratory tests cannot duplicate the wide variety of surges met in service. Standard test procedures. however, make it possible...
Download

IEEE 475-2000 pdf free

IEEE 475-2000 pdf free.IEEE Standard Measurement Procedure for Field Disturbance Sensors 300 MHz to 40 GHz. Abstract: Test procedures for microwave field disturbance sensors to measure radio frequency RF) radiated field strength of the fundamental frequency, harmonic frequencies, near field power flux density, and nonharmonic spurious emissions of sensors operating within the frequency range of 300 MHz to 40 GHz...
Download

IEEE 1277-2000 pdf free

IEEE 1277-2000 pdf free.IEEE Standard General Requirements and Test Code for Dry-Type and Oil-Immersed Smoothing Reactors for DC Power Transmission. Abstract: The electrical, mechanical, and physical requirements of oil-immersed and dry-type air core smoothing reactors for high-voltage direct current( HVDC)applications are specified. Test code is defined and appropriate technical background information is presented or identified. Keywords: construction, dry-type air core,...
Download

LEAVE A REPLY

Anonymous netizen Fill in information